This handbook describes how to install and use the Raymarine ST60+ Tridata instrument. This handbook describes how to operate, maintain and install the Raymarine ST60 Wind instrument and ST60 Close Hauled Wind instrument. Viii ST60 Wind & Close Hauled Wind Instrument Owner ’s Handbook. Iv ST60 Wind & Close Hauled Wind Instrument Owner ’s Handbook. Test at the connections on the rear of the display head, or at the base of the mast (if you have a junction box installed), making sure that everything is connected and powered. With the multimeter, check the following: Set the multimeter to the 20V DC scale. Normally the ST50/ST60/i60 display head would be energized and provide this 8V, however in your case, you may need to power the masthead transducer seperately. You will need to supply 8v to the masthead across the red and shield connections. The currently manufactured masthead transducer (shown below) may be serviced with part number A28167: To perform the check, you will need a multimeter, and a DC power supply. If cups are shaped hemispheres, then the part number for the service kit is A28167. If cups are shaped like trapezoids, then the part number for the service kit is E28081. Raymarine has produced two types of transducers for the ST60 Wind Instruments. Raymarine Masthead Wind Transducer Test Before performing the test below, the masthead transducer should be inspected to verify that its cups and/or vane has not been broken.